Screenshot 2026-08-05 011952.jpg
Screenshot 2026-08-06 003307.jpg
1/2

120/min Xiranite (14x29) Stashless/minPower "TetraGen Forge"

142

2

0

Создано 6 авг. 2026 г.
Обновлено 6 авг. 2026 г.

Note: If excluding depot loaders (e.g., direct feed into other facilities), dimensions of this design are 14 x 28. Also be aware that the "Facilities used" and "Input products" sections are incomplete due to this site's update status. OUTPUTS: 120/min Xiranite *(4 belts)* INPUTS: 6/min Inergen *(0.2/sec) (0.3 gas extractors assuming high purity)* 180/min Clean Water *(3/sec) (3 fluid pumps)* INSTRUCTIONS: NAEU Loader version: EFO01A5ieA3e8AE2E9ieO NAEU Loaderless version: EFO01o083oA3Uo6o7IieO Choose which version to use, and place it (default is loader). Connect the conduit adjacent the Gas Dispersing Unit to Inergen supply (one extractor can supply three dispersing units). Connect the conduit touching the edge of the design to one water pump, and connect the last conduit to two water pumps. Start the Yazhen/Jincao loops by placing 6-7 seeds/plants in either the Planting Units/Seedpicker Units, respectively. OVERVIEW: This design first and foremost is stashless (minimum power). To facilitate practicality for this aim, the design was developed with the objective of channeling all output to one edge. Finally, the design was made to be as dense and small as possible. Further optimization may still be possible if conduits are removed, though this should otherwise be near the limit for a stashless 4-forge design. APPENDIX: EnKAD link: https://beta.enka.network/endfield/aic/?id=Y2w0h5s9U9Q0T8

Комментарии (1)

Войдите, чтобы присоединиться к разговору.

@user_2oX7THdWD1fkCqOO

12 авг. 2026 г. (отредактировано)

It's nice and compact, but something is broken with the water flow. I suspect it has to do with the pipe being only 1 unit long between the first and second splitter, making it split one unit between three forges. I've triple checked my pumps and let it run overnight to see if it balances out. It did not. Each conduit is connected to either 1 or 2 pumps, not some 3/2 split. If it were a case of the conduit feeding four facilities only getting water from one pump, then three of the forges would be slow; however only the two nearest the loaders are. Logically, the flow should balance out. Unfortunately, some game mechanic is preventing it from doing so. Personally, I have mitigated the issue by using more conduits, including two outside of the base border to feed the top six forges.